A Revolutionary Neural DAQ System

The platform has been designed to support constantly evolving neuroscience research, accompanying you in your journey in the lab as well as in clinics and healthcare institutions.

With Alpha Omega's data acquisition system, you can:

  • Configure the system based on your immediate experimental and budget needs
  • Choose from a variety of packages and software features

*Online Exclusive Prices

Price for
Data Acquisition System Unit
?Small size and portable Data Acquisition System
Software
?Modern, integrated  and User friendly software, with a customizable workspace
Impedance Measurement
?One-Click online impedance check for all contacts and channels
Sampling Rate
?30000 Hz per channel
Digital Outputs
?A Digital/Analog Input/Output board for general purpose
Analog Outputs
?A Digital/Analog Input/Output board for general purpose
Digital Inputs
?A Digital/Analog Input/Output board for general purpose
Analog Inputs
?A Digital/Analog Input/Output board for general purpose
Experiment Control
?- Embedded digital and analog input that allow connection to external sensors
- SDK enables access and control of sensors and actuators
SDK & Online data streaming (Application development environment)
?- Programing interface open to multiple environments and languages (MATLAB/C++/C#//Python
- Online data streaming for real time processing
- Support BCI/BMI applications
- examples are available
Online Spike Sorting
?based on 8 Point Template, with up to 4 different templates for each channel
Online & Flexible Filtering
?Real-time streaming of 4 signal types for each contact (RAW, Spikes, LFP, and Segmented spikes)
Online Analysis Display
?PSTH, Evoked potential, spike raster, spike firing rate, XY display
HeadStages
HeadStage Ports
?Number of headstage ports on the main-unit, allowing you to connect headstages to the alphaRS main unit 
Support
?Online video-call training
High Performance Work Station
?PC  minimum specifications -
OS: Windows 10 pro 64bit
CPU: i7, Base clock 2.6Ghz, 8 core
RAM: 16 GB DDR 4
Disk: 512 GB NVMe SSD
NeuroExplorer License
?Online and offline Analysis
Stimulation
?Integrated Recording and Stimulation in one system: Using one software to control all channel’s modes
Warranty
?Coverage for all repair costs on all parts and equipment that is not the result of improper handling or misuse
Lease to Purchase
?24 months
Incept
Supports 256 Channels
20220629144238.131.png
20220629144238.131.png
30,000 Hz Per Channel

4* TTL 4 Digital output, 2* Analog Input, 2* Analog Output

2 outputs ± 5.0 V, 16-bit analog outputs

2 digital input channels (TTLs), 16-bit digital input port

2 differential analog input channels with 16-bit resolution and a dynamic range of ±5V
20220629144238.131.png
20220629144238.131.png
RAW
64 Channel HeadStage
4 ports
Add-on
12 Months
Nucleus
Supports 512 Channels
20220629144238.131.png
20220629144238.131.png
30,000 Hz Per Channel
8* Digital out, 4* Analog out, 4* TTLs, 16-bit port, 8* analog inputs
4 outputs ± 5.0 V, 16-bit analog outputs
4 digital input channels (TTLs), 16-bit digital input port
4 differential analog input channels with 16-bit resolution and a dynamic range of ±5V
20220629144238.131.png
20220629144238.131.png
RAW
20220629144238.131.png
2* 32 Channel headstages
8 ports
up to 8 hours
Add-on
Add-on for 1 stimulation source
12 Months
$940/month
alphaRS Pro
Supports 512 Channels
20220629144238.131.png
20220629144238.131.png
30,000 Hz Per Channel
8* Digital out, 4* Analog out, 4* TTLs, 16-bit port, 8* analog inputs
4 outputs ± 5.0 V, 16-bit analog outputs
4 digital input channels (TTLs), 16-bit digital input port
4 differential analog input channels with 16-bit resolution and a dynamic range of ±5V
20220629144238.131.png
20220629144238.131.png
Up to 128 Channels
RAW, Spikes, LFP, and Segmented spikes
20220629144238.131.png
Add-on
8 ports
Priority Customer Care
20220629144238.131.png
20220629144238.131.png
Add-on for unlimited sources
12 Months
Contact US